A rising of heat pipes thermal conductivity from 0. Experimental investigation of a novel magnetically. A new type of variable conductance heat pipe, the liquidcontrolled. Variable conductance heat pipes get their temperature control features from the expansion and contraction of noncondensable gas in the condenser of the heat pipe. Variable conductance heat pipe for a lunar variable. The increase in the thermal conductivity of the heat pipes from 0. A variable conductance heat pipe vchp is a variation of a heat pipe possessing some inherent temperature control abilities2. Pdf a vapor modulated loop heat pipe vmlhp is a loop heat pipe lhp incorporating a pressure regulating valve prv at its evaporator outlet. These pressures normally refer to values in perhaps notional plenums at the entrance and exit of a duct or a system fitting such as a valve.
The attached details of the heat pipe are explained in the following section. In a variable conductance heat pipe vchp a noncondensable gas ncg is added to the heat pipe, in addition to the working fluid. Investigation of the performance of a gas loaded variable conductance heat pipe by keith earl reynolds lieutenant commander, united states navy b. First of all the values iv and qv iv and qv is the voltage representing current need to be converted to current. Pulsating heat pipes phps or oscillating heat pipes ohps are. Heat pipe advanced radiator element consisting of a 50ft. Numerical analysis of thermal performance of flat heat pipe.
Investigation of the performance of a gasloaded variable. Pdf basic principles of heat pipes and history researchgate. Allows direct contact with heat source 1piece vapor chamber 10mm bend radius along. This analytically based routine is compared with data from a cylindrical heat pipe with a crescentannular wick that undergoes gradual quasisteady transitions through the viscous and condenser boundary heat transfer limits. The relevant parts of the following applicable documents at their.
The temperature transfer matrix was obtained for the air preheater that comprises several discrete heat. University of america for her endless support in obtaining few documents from. The proposed model provides a calculation method for the thermal distortion analysis of heat pipes applied in the motorized spindle. Heat pipes with variable thermal conductance property for space. Interchangeable variable conductance heat pipes for sodiumsulfur batteries 2. Conductance calculation molecular flow, long tube of. Necati ozisik, why do not you tell to others about this way. Variable conductance heat pipe, rotating heat pipe, loop heat pipe, micro heat pipe, nanofluids 1. Convection heat transfer microelectronics heat transfer. Transient performance of gasloaded, variable conductance heat pipes with a hot reservoir h. Reduced power precision temperature control using variable. The conductance g of the dielectric material separating the two conductors is represented by a shunt resistor between the signal wire and the return wire siemens per unit length. Parallel conductance is simply a different viewpoint of parallel resistors. Depending on the operating conditions, the ncg can block all, some, or none of the available condenser length.
A variableconductance heat pipe system vchps and its design have been. Heat pipe thermal buses were proposed to facilitate a con. The formular gives the conductance of pipes which are constant cross section, as well as in which the circumference and cross section of the pipes are increasing or decreasing function of the pipe length. Investigation of gravitational effects on the performance. In this heat transfer and t5hermal conductivity analysis were carried out in concentric circular tube logged with saw dust and asbestos between the pipes. The first law in control volume form steady flow energy equation with no shaft work and no mass flow reduces to the statement that.
Thermal contact conductance microelectronics heat transfer. You see a pipe with sticking1 on both sides, and desorption from one side. A pulsating heat pipe php is a passive twophase heat transfer device for handling moderate to high heat fluxes, typically suited for power electronics and similar applications. Analytical heat transfer mihir sen department of aerospace and mechanical engineering university of notre dame notre dame, in 46556 may 3, 2017. Experimental papers on artery and groove wicks and on rotating heat pipes were also notable. The working fluid repeatedly vaporizes and condenses as a. A heat pipe is a device that effortlessly transports thermal energy from its one point to the other.
A heat pipe is a heat transfer device that combines the principles of both thermal conductivity and phase transition to effectively transfer heat between two solid interfaces at the hot interface of a heat pipe a liquid in contact with a thermally conductive solid surface turns into a vapor by absorbing heat from that surface. In this design, the vacuum insulation consists of a permanently sealed, thin sheet steel, evacuated envelope of whatever geometry is required for the application. When you use the quick pipe from the menu, what you get is in fact a conductance example. I want to calculate the admittance, impedance, conductance, resistance, susceptance and reactance. It appears primarily in fouriers law for heat conduction. Pdf vapor modulated variable conductance loop heat pipes. Heat transfer and flow analysis in loop heat pipe with. The treatment has been comprehensi ve, involving theoreti sal andor experimental studies in hydrostatics, hydrodynamics, heat transfer into and out of the pipe, flid selection, and materials compatibility, in addi tior. Types of heat pipes thermosyphon leading edge rotating and revolving cryogenic pumped loop heat pipe flat plate micro heat pipes variable conductance capillary pumped loop heat pipe 16. Thermal performance of a miniature variable conductance loop. Onedimensional heat conduction for onedimensional heat conduction temperature depending on one variable only, we can devise a basic description of the process. Variable conductance heat pipes variable conductance issues vchp differ from normal hp by their thermal control capability.
A formular for the conductance calculation in molecular flow is presented. To keep setpoint temperature of a heat source mounted on the evaporator almost constant, independent of changes of the boundary conditions i. At any cross section of the heat pipe, a pressure differential exists between the vapor and liquid phases. The properties must be defined in external data files. This allows the heat pipes to act as thermal switches without additional constructive elements. Vertical heat pipe vhp cooling input data heating input data cooling output data heating output data revesion 2. Design of a variable conductance heat pipe for a photonic component martin cleary, ronan grimes university of limerick stokes research institute marc hodes bell laboratories abstract in conventional vchp applications either the heat dissipation of the device being maintained at constant temperature or the ambient temperature varies, however, in. It applies the implied heat of the vaporized working fluid instead of the reasonable heat. The treatment has been comprehensive, involving theoretical andor experimental studies in hydrostatics, hydrodynamics, heat transfer into and out of the pipe, fluid selection, and materials compatibility, in addition to.
Heat pipes rely on a temperature difference between the ends of the pipe, and cannot lower temperatures at either end below the ambient temperature hence they tend to equalize the temperature within the pipe. Introduction a typical heat pipe consists of a sealed pipe or tube made of a material that is compatible with the working fluid such as copper for water heat pipes, or aluminium for ammonia heat pipes. Alkali metal heat pipes, variable conductance heat pipes, radioisotope stirling systems, nak heat pipes, advanced stirling radioisotope generator, space radiator systems pacs. Passive heat exchanger temperature control using variable. Reduced power precision temperature control using variable conductance heat pipes article in ieee transactions on components, packaging, and manufacturing technology 312. Conductance heat pipe cchp, it is wise to start with the layout of a cchp. An alkalimetal variable conductance heat pipe vchp was designed to allow multiple stops and restarts of the stirling engine. The sigma thermal control heat rejection device is a variable conductance heat pipe vchp radiator 0. You can tell others to visit this site and go with browsing them preferred books heat conduction, by david w. Theory and design of variable conductance heat pipes.
The status of the ongoing effort in developing this. It usually consists of a meandering capillary tube, closed endtoend in a loop, evacuated and then partially filled with a working fluid. May 21, 2011 the heat transfer analysis of variable conductance heat pipe air preheater was carried out. Heat pipes with variable thermal conductance property. Thermal conductivity is measured in watts per kelvinmeter wk. Full text of investigation of the performance of a gas. Experimental investigation into the feasibility of using a. The importance of heat pipes as devices for effective heat transfer has led to development of various types of them such as loop heat pipes, wick type heat pipes. Its the same circuit configuration, but uses a different equation.
In the bottom right corner, you can see the transmission probability percentage of molecules traversing the tube calculated. Pdf this dissertation investigated experimentally and theoretically. Flanges can be added on the outer surface for easy integration with instruments or radiators the flange is an integral part of the extrusion. Applications for vchps include passively controlling temperature, providing over temperature protection, acting as a variable thermal link, and helping heat pipe startup from a frozen state. By using the temperature transfer matrix, the outlet fluid temperatures could be easily calculated.
When the vchp is operating, the ncg is swept toward. Regulative characteristics of methanol copper heat pipes. Variable conductance heat pipes for variable thermal links. Variable conductance heat pipes vchps are used to passively maintain. Miniature heat pipe is defined as a heat pipe with a hydraulic diameter in the range of 0. The performance of the heat pipe is investigated at three different amounts of both heat input and mass of noncondensable gas air. C is conductance in literspersecond d is the tube inner diameter in inches l is the tube length in inches so, for example, d is 2.
Investigation on heat transfer and thermal conductivity. Generally speaking, vacuum chambers are connected to a vacuum pump via piping. What links here related changes upload file special pages permanent. The glast model was delivered along with a library file containing a proprietary vchp routine. Experimental investigation of thermal performance of variable. Heat pipes hardware m t l l i t b ith th i fmetal aluminum tube with grooves on the inner surface cold t ild extrusion grooves are filled with the working fluid water, ammonia, propylene, etc. Both constant conductance cchp, also called fchp, with or without noncondensible gas ncg, and variable conductance vchp pipes. Introduction loop heat pipe is an efficient heat transfer device. After understanding this very simple method to check out as well as get this heat conduction, by david w. Equivalent thermal conductivity of heat pipes springerlink. C 75 x 820 30 literspersecond conductance limitations on pumping speed the in. Heat pipes are twophase heat transfer devices which have advantages such as high conductance and the ability of heat transfer in small temperature differences between the evaporator and the condenser. A vchp was designed for the advanced stirling radioisotope generator, with a 850 c heater head temperature.
Heat pipe 1piece vapor chamber 2piece vapor chamber 20 heat pipes bend radius 3x diameter of heat pipe. In this aspect, heat pipes with variable conductance properties such as the. Development of a variableconductance heatpipe for a sodium. Experimental analysis of closed loop pulsating heat pipe with variable filling ratio dharmapal a baitule 1 and pramod r pachghare corresponding author. Historically, lhps were considered primarily as candidates for high power, high adverse elevation and high heat flux applications such as deployable radiators for. Various fluids are used in heat pipes and the selected fluid is based upon its saturation temperature and the temperature at which the heat pipe will be functioning. Flow resistance occurs as a result of external friction between gas molecules and the wall surface and internal friction between the gas molecules themselves viscosity. Kamaraj b indian institute of technology madras, a refrigeration and airconditioning laboratory, department of mechanical engineering, b department of metallurgical and materials engineering, chennai, tamilnadu, india 60036. This paper describes one approach to the design of a variable conductance vacuum insulation. This page contains heat pipes seminar and ppt with pdf report. Introduction there is a vast requirement of miniature equipment in electronic devices for cooling purpose so pulsating heat pipe can significantly used for cooling purpose. Heat pipes seminar ppt with pdf report study mafia. High temperature variable conductance heat pipes for.
There are four components that fully describe a transmission line they are independant of each other and nontransferrable. Conductance of tube, calculation of conductance,conductance. This study has clarified that titanium is very desirable as heat pipe material for use in space. A heat pipe is a heattransfer device that combines the principles of both thermal conductivity. There are three sections of a basic heat pipe with a working fluid enclosed inside the pipe.
Both constant conductance cchp, also called fchp, with or without noncondensible gas ncg, and variable conductance vchp pipes can easily be simulated. Thermal performance of a miniature variable conductance loop heat pipe 2000012490 loop heat pipes lhp of different designs are currently used in aerospace applications worldwide. Pdf variable conductance heat pipes for radioisotope. Performance tests for a screen wick pipe, gravity pipe, and rotation heat pipe are done to validate the efficiency of the equivalent thermal conductivity model. Development of an elevated temperature loop heat pipe for space. Heat pipe routines built into sindafluint provide fast systemlevel solutions to modeling heat pipes when a full twophase solution is not required. Variable thermal conductance link for lunar landers and. Experimental investigation of thermal performance of. At the time, there was no good method for sealing a refractory metal heat pipe, so a lower temperature valve was left on condenser end of the heat pipe. Variable conductance heat pipes for radioisotope stirling. Typically, micro heat pipes, figure 9 have convex but cusped cross sections for example, a polygon, with hydraulic diameter in range of 10 to 500. In the conventional type, a small volume of working fluid is sealed into an evacuated metal container.
An introductory guide to variable conductance heat pipe. A simple and concise routine that approximates the response of an alkali metal heat pipe to changes in evaporator heat transfer rate is described. Thermal conductivity 1 thermal conductivity in physics, thermal conductivity, is the, property of a materials ability to conduct heat. Introduction this paper presents the design of a variable conductance heat pipe vchp that will provide backup cooling for. Numerical analysis of thermal performance of flat heat pipe d.
Convection heat transfer reading problems 191 198 1915, 1924, 1935, 1947, 1953, 1969, 1977 201 206 2021, 2028, 2044, 2057, 2079 introduction in convective heat transfer, the bulk. The vapor then travels along the heat pipe to the cold interface. A variable thermal link between the web and the radiator 3. They provide variable conductivity by utilizing the physical heat transfer limitations. Separation of variables for heat conduction in a finite bar. Loop heat pipe, multiple evaporators, thermal conductance, network model analysis, two phase flow. A primer on variable conductance heat pipes vchps, discussing their operation and limitations, with an animated schematic.
For sigma, six heat pipes are used with a l geometry, a total length of 2. An alkalimetal variable conductance heat pipe vchp is under development to allow multiple stops and restarts of the stirling convertor. Variable conductance heat pipes vchps are the main part of mascot mobile asteroid surface scoutlander passive thermal control system tcs. The variable conductance heat pipe vchp, sometimes called a specific variant the gascontrolled or gasloaded heat pipe, has a unique feature that sets it apart from other types of heat pipe. Heat loss calculations and principles ced engineering. When heat is supplied to the evaporator, the working fluid vaporizes, and travels to the condenser, where it condenses. A vchp was designed for the advanced stirling radioisotope generator. Variable conductance heat pipes vchps for spacecraft thermal control typically have a coldbiased reservoir for the noncondensable gas ncg at the end of the condenser. The liquid pressure decreases as it flows from the condenser to the evaporator. A radiator to reject heat possible thermal links variable conductance heat pipes vchps loop heat pipes lhps thermal switch pumped loop. An introductory guide to variable conductance heat pipe simulation. The conductance viewpoint looks at a parallel resistor and instead of seeing a 1r term in the parallel resistor formula, it sees a g 1r term. Heat pipe selection guide pdf heat pipe basics and demonstration. The particular application of hps is the removal of heat.
In 1975, under contract nas28310 to ames research center, tfypi fabricated and tested two prototype vapormodulated heat pipes which achieved variable conductance by. The heat pipe developed is titanium ammonia gas loaded variable heat pipe which has a heated reservoir vchp. Variable conductance heat pipes heat pipe manufacturer. The actual test results of heat pipe with different wick structure athorizontal and vertical gravity assist orientations. Listoffigures figure page 1 conventionalheatpipeoperatingdiagram 11 2 variableconductanceheatpipe operatingdiagram 11 3 photographofheatpipeinhorizontal position 18 4. Introduction the basic heat pipe is a closed container which has evacuated all noncondensable gases and contains a capillary structure wick and a small amount of a vaporizable fluid 1. Pdf nak variable conductance heat pipe for radioisotope. Analysis and application of variable conductance heat pipe. Heat pipes employ phase change to transfer thermal energy from one point to another by the vaporization and condensation of a working fluid or coolant. Separation of variables for heat conduction in a finite bar with insulated ends xuyan chen. Transient performance of gasloaded, variable conductance.
This is its ability to maintain a device mounted at the evaporator at a near constant temperature, independent of the amount of power being generated by. Variable conductance heat pipe vchp variable conductance heat pipes vchps are similar to standard heat pipes, with the addition of a noncondensable gas ncg. Conductance in a transmission line electrical engineering. The vapor pressure decreases as it flows from the evaporator to the condenser. The thermal conductivity, specific heat, and sound velocity of crystalline chrysotile asbestos made up of hollow tubular fibrils of composition mg3si2o5oh4 have been measured at temperatures of. Variable conductance or temperature controlled heat pipe was first described by block and. The temperature transfer matrix was obtained for the air preheater that comprises several discrete heat transfer units with same or different heat transfer surface area in a parallel or counter flow mode. The heat transfer from one pipe to other pipe is depends on supplied heat input, the temperature difference and the thermal conductivity of the insulation and the pipe material.
1051 181 814 1074 387 359 1003 1134 1374 172 804 250 1446 1017 321 64 1136 276 406 1255 776 689 1499 827 565 1161 1474 929 572 998 91 660 631 360 246 1024 930 638 1466